![]() | | | | Ultrasonic Nebulizers, Alternating Pressure Mattress, Patient Monitor, Fetal Monitor, Ultrasonic Instruments, Suction Machine, ECG Machine, Wheel Chairs, Nursing Bed Series, Walker and Waking Aids, Comprehensive Nursing Series, Shadowless Operation Lamp, Oxygen Intake Device, Operating Table, Pulse Oximeter, | ![]() | | | | X-RAY Illuminator, X-ray Film Cassettes, Intensifying Screen, Dark Room Accessories, Developing Film Hanger, X-ray Film Processor, Medical X-RAY Machine, Medical X-RAY Camera, X-RAY Protective Accessories, X-ray Film Processing Machine, Sensitive X-ray Film, | ![]() | | | | | ![]() | | | | | ![]() | | | | Disposable Syringe, Disposable Infusion Set, Disposable Tubings, Disposable Hypodermic Needle, Disposable Gloves, Extracorporeal Circuit, Enaesthesia Use, Blood Collection Tube, Gynecology Products, Urological Products, Safety Condom, | ![]() | | | | | ![]() | | | | Cotton Products, Elastic Bandage, First Aid Bag, First Aid Plasters, Gauze Products, Orthopaedic Bandage, Wound Care Plaster, Surgical Tapes, Transparent Island Dressing, Transparent Semi-permeable Dressing, Surgical Film, Non-woven Adhesive Wound Dressing, | ![]() | | | | | ![]() | | | | | ![]() | | | | |
|
|
|
| |  | | Name:Single Channel Digital ECG Machine |
|
|
| |

| Name:Single Channel Digital ECG Machine | | Code:MST3333427 | | PRODUCTS INTRODUCTION: | Single channel with measurement report
Build in rechargeable Ni-MH battery
Chinese/English language
Simultaneous 12 leads
20X2 character LCD
Paper size: 50mmX20/30m
Built in RS232 interface (USB is optional)
Dimension:288mmX204mmX60mm
Packing:380mmX300mmX210mm
Weight:4.3kg(gross); 3.27kg(net)
Specification
| Items |
specification |
| Lead |
standard 12 leads |
| lead acquisition |
synchronously 12 leads |
| Data acquisition |
18bit/1000Hz |
| Record mode |
Manual mode; Auto 1; Auto 2; Auto 3 |
| Filter |
AC, EMG,Drift Filter |
| CMRR |
100dB(with AC filter) |
| Input circuit |
Floating; Protection circuit against Defibrillator effect |
| Input circuit current |
≤0.1μA |
| Input Impedance |
≥2.5MΩ |
| Patient current leakage |
<10μA |
| Calibrating voltage |
1mV±2% |
| Voltage Tolerance |
±500mV |
| Time constant |
>3.2s |
| Frequency response |
0.05 ~150Hz |
| Noisy level |
≤15μVp-p |
| Sensitivity valve |
≤20μV |
| Inter-Channel Interference |
≤0.5mm |
| Paper speed |
25、50mm/s(±3%) |
| Sensitivity |
AUTO,2.5,5,10,20mm/mV |
| Recording mode |
Thermal Array printing |
| Paper specification |
50mmx20m,roll |
| LCD display |
20x2 character LCD,display status. |
| Safety classification |
IEC60601-1 class I, type CF |
| Power supply |
AC : 110V/220V/85~265V,50/60Hz±1Hz;30VA |
| DC :12V(1500mAh) rechargeable Ni-MH battery |
| Fuse |
AC extend T500mA/125V ¢5x20mm
AC extend T250mA/250V ¢5x20mm